This training is also beneficial for as well as safety managers, superintendents, and individuals planning to apply for New York City Master or Special Rigger’s license.Ĭourse Completion Process: Upon successful completion of the course (in 2-3 business days), participants will receive a 32-Hour Suspended Scaffold Supervisor course completion picture ID card that will be valid for 4 years. This course is geared towards experienced workers interested in suspended scaffold project supervision with at least one year of practical experience in hoisting and rigging. Who Should Attend This 32-Hour Suspended Scaffold Supervisor course?
#Nyc supported scaffold inspection checklist how to
Students will identify ways to read scaffold design drawings, how to verify the fitness of the rigging crew, properly train workers on related hazards, and also how to identify and respond to emergency situations. This system, DOB NOW: Inspections provides the ability to request and cancel appointments online, as well as view inspection results and documentation.Why Should You Take This 32-Hour Suspended Scaffold Supervisor course?Īs per 3314.4.5.3 of the 2014 NYC Construction Codes, this 32-Hour Suspended Scaffold Supervisor course is required by the New York City Department of Buildings (DOB) to supervise suspended scaffold projects on construction sites in New York City.During this course, participants will develop the core management skills required to be an effective supervisor of suspended scaffolding operations. Inspection RequestsĪn online tool for scheduling appointments for required DOB inspections must be used.

Temporary Construction Equipment projects may require a final inspection by the NYC Department of Transportation (DOT). The applicant must submit revised ‘As-Built’ drawings prior to project sign-off. If the completed project has changes that are not significant or substantive, an ‘As-Built’ submission shall be allowed. Such self-certified inspections may be audited audit results will be provided to applicant and must be resolved prior to final sign-off.ĭepending on the above, DOB or the applicant shall complete the final sign-off inspection to close the project. If the applicant elected to self-certify the required DOB inspections, an online notice of intent to self-certify must have been submitted at the project start. Such inspection requests may be made online, and any objections raised may be resolved online. Submission of Special Inspections can be done online by Special Inspection Agency.ĭOB inspections may be required during various project stages. See other Project Guidelines for associated DOB Inspections.Įxcept for Temporary Hoistways, Construction Equipment projects do not require a final inspection. There are no required DOB inspections solely for the use of construction equipment. However, there may be required DOB inspections for associated projects that utilize construction equipment such as demolition or new construction. where the stability or integrity of a structural system is to be temporarily diminished, in accordance with Sections BC 1704.20.6 through 1704.20.10. If restrained either horizontally or vertically, alteration of existing structural systems or elements, such as columns, beams, bearing walls, seismic isolation, etc.
#Nyc supported scaffold inspection checklist verification
The special inspection shall include the verification of compliance with approved construction documents and standards established by the commissioner pursuant to Section AC 28-113.2.2. The installation of post-installed mechanical anchors, adhesive anchors, and screw anchors shall comply with BC Table 1704.32.
#Nyc supported scaffold inspection checklist code
Per BC 1704.1.2, the Contractor cannot hire the special inspector.īased on the scope of work, a scaffold project may be required to comply with the following Special and Progress Inspection requirements:Ī Special Inspection is required per BC 1704.14 when the proposed Scaffold’s materials and systems are alternatives to materials and systems prescribed by this code for unusual design and/or materials and systems required to be installed in accordance with additional manufacturer’s instructions with requirements not contained in the building code or in standards referenced. The Applicant of Record may perform these inspections if they are also an SIA.

Prior to Approval, the Applicant of Record is required to identify all required Special and Progress Inspections ( BC 1704.1). Prior to DOB permit issuance, the owner must typically engage a registered Special Inspection Agency (SIA) who will take responsibility for the Special and Progress Inspections. Scaffold Work & Inspections Special and Progress InspectionsĪs per Chapter 17 of the Building Code, scaffold work may require certain Special and Progress Inspections to be performed during and at the end of construction as outlined in the table below.